Ramsey UT5A — Ramsey UT5A Ultimate 555 Timer Kit Manual — User Guide PDF

low (approximately 0VDC). The Low appears at J4 pin 1 as the Non-inverted Timer Output. If U1’s pin3 output is High, the base of Q2 is High, causing it to be turned on. This pulls Q2’s collector Low, and this Low (approximately 0VDC) is applied to J5 pin2 as the Inverted Timer Output. If JMP7 is installed, this Low (approximately 0VDC) is applied to the base of Q3, turning it off. This allows pull-up resistor R12 to pull Q3’s collector High (approximately +V). The High appears at J4 pin 1 as the Non-inverted Timer Output. The Inverted Timer Output at J5 pin2 and Non-Inverted Timer Output at J4 pin1 can be used as logic level outputs.

A Low is less than 200mV and a High is from +3 to +24V, depending on the supply voltage used for V+. They also can be used to drive a load of up to 200mA if the load is connected between +V pin at J4 pin2 and either of the Timer Output pins. To have the load active when the timer’s output at U1 pin3 is High, connect the load between J4 pin2 and J5 pin2. To have the load active when the timer’s output at U1 pin3 is Low connect the load between J4 pin2 and J4 pin1. D3 and D4 protect Q2 and Q3 respectively from inductive kick if an inductive load is used. MODES OF OPERATION Note: For these explanations we will assume no Control Voltage input. Only basic operation is covered here.

Monostabe Mode: In Monostable mode the timer acts as a “one shot” pulse generator. It has one Stable and one Unstable state. The pulse begins with a negative input trigger. This causes the output of the 555 timer to go from low to high starting the pulse (Unstable). The Pulse Width is determined by the charging network’s RC time constant. When the circuit times out the output of the 555 timer goes from high to low completing the pulse (Stable). The timer will remain in this Stable state until it is triggered again. In Monostable mode the 555 timer requires an external negative pulse or spike to start its operation.

We will be using the pulse provided by the Input, Differentiator, and Limiter circuit previously described. This means JMP4 (Input Select) must be installed. JMP6 (Mode Select) set to pins 1 and 2 prepares the Charging Network for Monostable operation. The C2’s charge path can be traced by starting at +VCC down through R4, R5, to the pin7 (Discharge) of the timer IC, through JMP6 pin1 to pin2, to C2. You may notice that R6 and R7 are bypassed in this mode. C2 is also directly connected to pin6 (Threshold) of the timer IC. When C2 is charging the Monostable is in its Unstable state. C2 is allowed to charge when U1 pin3 (Output) is High and pin7 (Discharge) is providing an UT5A 7