Ramsey UT5A — Ramsey UT5A Ultimate 555 Timer Kit Manual — User Guide PDF

Pulse Width and begins Rest Time by setting Out to Low and grounding Discharge. C2 now discharges through R7, R6, U1 pin7, to ground in the 555 timer, back to C2. When C2 reaches Trigger level Rest Time comes to an end and we begin the process over again. Formulas for calculating Pulse Width (PW) and Rest Time (RT) follow (assuming no control Voltage used): PW = 0.693 * C2 * (R4 + R5 + R6 + R7) RT = 0.693 * C2 * (R6 + R7) Total Time (T) can be calculated as: T = PW +RT Or T = 0.693 * C2 * [(R4 + R5) + 2(R6 + R7)] Frequency (f) can be calculated as: 1 1 _ f = T = 0.693 * C2 * [(R4 + R5) + 2(R6 + R7)] Duty cycle is the ratio of Pulse Width to Total Cycle time, it can be calculated as:

R4 + R5 + R6 + R7 DC = R4 + R5 + 2(R6 + R7) * 100% UT5A 9