CAUTION The setpoint is specified with the same accuracy as for counting physical values.. The multiplier can be set from 0.00001 to 99999. The conversion of counting results (result of multiplying) will be rounded up. Read more about each of the counting modes, see section 7.2 . The counter also filters the input signals with two filters. The first one filters the signal on the counting input by pulse duration (from 1 to 50,000 Hz), the second filters signal on the control inputs of the device (from 1 to 999999 microseconds). 7 Setup 7.1 Sequence of setup The Setup mode is intended for viewing and editing the device parameters. New parameters are saved to non-volatile memory of the device.

To enter (or exit) the Setup mode, press and hold button for at least 2 seconds. For access to configuration setup (parameters of connection with PC) press at the same time buttons and and hold them for 2 sec. While editing, if no button is pressed within 2 min., device automatically restores previous value of the parameter and returns to parameter view mode. If within 3 minutes there are no actions in Setup menu, device automatically returns to Operation . 36