Delta Electronics — 9.3.3.2 Communication LED Indicator

Chapter 9 Ethernet Specification and Operation 9.3.4 EtherNet Communication Port 9.3.4.1 Communication Port Pin Assignment Delta EtherNet/IP devices use CAT5e industrial Ethernet cables and can be connected via RJ-45 communication port. 9.3.4.2 Communication LED Indicator 9_ Note: The LED indicator is at the RJ45 connection. 9-13 Error Indicator System Fail (SF): Red; Bus Fail (BF): Red Max. IO Slot Supported 17 Register to Read and Write AS300 series data registers are supported to read and write Minimum Time for Data Exchange to Operate 10 ms Maximum Data Length/Per Transmission Input: 250 words Output:

250 words PROFINET Configuration Download PROFINET Configurations from PN Controller Pin Signal Description Pin Signal Description 1 Tx+ Transmit plus 5 -- N/C 2 Tx- Transmit negative 6 Rx- Receive negative 3 Rx+ Receive plus 7 -- N/C 4 -- N/C 8 -- N/C LED Indicator LED Status Description LINK Green ON  Communication port is connected.  Connected to Ethernet OFF  Communication port is not connected.  Not Connected to Ethernet ACK Yellow Blinking  Packets transmitting/receiving  Packets transmitting/receiving over Ethernet OFF  No packets transmitting/receiving  No packets transmitting/receiving over Ethernet