AS Series Operation Manual Emergency response data 10.4.4 Example of Sending SDO through the Ladder Diagram 1. Control Requirement: Read the value of P0-09 from the servo through SDO. 2. Hardware Connection: 3. The Corresponding Relation between Slave Parameter and Index/Subindex The index_subindex corresponding to P0-09 in servo is 2009_0. In the CANopen Builder network configuration software, right click the servo icon, and then click Parameter Edit . In the Parameter Edit dialog box, you can see the index_subindex corresponding to the servo parameter.
For more details on how to operate the network configuration interface, refer to Section 11.1.1 in the CANopen Builder software help file _10 10-26 Response message PLC device High byte Low byte D24000 Message header ResID=01 Status code =01 D24001 Reserved =0 Size =2A (Hex) D24002 Type =04 Node ID =03 D24003 Message data Total number of data =1 Number of data stored =1 D24004 Datum 1=54 Datum 0=42 D24005 Datum 3=20 Datum 2=14 D24006 Datum 5=0 Datum 4=0 D24007 Datum 7=0 Datum 6=0