Chapter 10 CANopen Function and Operation 4. The Structure of the Request Message Devices: 5. Editing the Ladder Diagram in ISPSoft When M2=ON, after reading succeeds, the program stores the data from the target device in D24000– D24005. The value of D24005: 100 ( hex ) is the value read from P0-09. 6. The Structure of the Response Message Devices:
10 10-27 Content Explanation PLC device (Hex) High byte(Hex) Low byte(Hex) SDO request message mapping area D25000 0101 ReqID = 01 Command = 01 D25001 0004 Reserved Size = 04 D25002 0102 Type = 01 Node ID = 03 D25003 2009 Index high byte = 20 Index low byte = 09 D25004 0000 Reserved Subindex = 00 Content Explanation PLC device (Hex) High byte(Hex) Low byte(Hex) SDO response message mapping area D24000 0101 ResID = 01 Status code = 01 D24001 0006 Reserved Size = 08 D24002 4303 Type = 43 Node ID = 03 D24003 2009 Main index high byte = 20 Index low byte = 09 D24004 0004 Reserved Subindex = 00 D24005 0100 Datum 1= 01 Datum 0= 00