AS Series Operation Manual _12 12-12 19F4 CANopen communication is in the BUS- OFF state. 1. Check if the network cable is normal and the shielded cable is grounded. 2. Check if the start and end of the network cable are both connected with a 121Ω terminal resistor. 3. Check ifall the nodes share the same baud rate on the network. - V 19FB The sending registers exceed the range. Revise the time to synchronize (suggested to use a longer time). - V 19FC The receiving registers exceed the range. Revise the time to synchronize (suggested to use a longer time). - V 2001 Not using the FCOMP card or not in the right mode for the ASDA-A2 while using the CANopen communication instruction. 1.
Use the FCOMP card in the function card slot to check if the operation mode is correct. 2. Check the syntax error step in the program. Modify and compile the program and then download the program again. SM0 V 2003 The device used in the program exceeds the device range. Check the syntax error step in the program. Modify and compile the program and then download the program again. SM0 V 200B The operand n or the other constant operands K/H exceed the range. SM0 V 200C The operands overlap. SM0 V 200D The binary to binary-coded decimal conversion is incorrect. SM0 V 200E The string does not end with 00.
SM0 V 2012 Incorrect division operation SM0 V 2013 The value exceeds the range of values that can be represented by the floating- point numbers. SM0 V 2014 The task designated by the TKON or YKOFF instruction is incorrect or exceeds the range. SM0 V 2017 The instruction BREAK is written outside of the FOR-NEXT loop. SM0 V 2027 No such position planning table number or the format is incorrect. 1. Check the syntax error step in the program. Modify and compile the program and then download the program again. 2. Check the settings of the position planning table. SM0 V 2028 High speed output instruction is being executed. Only one instruction can be executed at a time.
Refer to SR28 for the record of the axis number and rearrange the output control procedures. - V 2030 During the execution of CSFO instruction, the output frequency exceeds the upper limit. Modify the ratio of input / output frequency or lower the inut frequency value. - V 2031 During the execution of CSFO instruciotn, when the output frequency is set to 0, but even after 2 seconds, the output is still not complete. - V 6004 The IP address filter is set incorrectly. Set the Ethernet parameter for the CPU module in HWCONFIG again. SM1108 X 600D RJ45 port is not connected. Check the connection. SM1100 X