AS Series Operation Manual Electrical specifications for the inputs _2 Electrical specifications for the SSI input and output *1: V ID is the voltage difference between DATA+ and DATA-. 2-61 Model Pulse input External input Item Number of inputs 4 (A+/B+, A-/B-) 2 (Z+/Z-) Connector type D-sub 15 Input current 5-24 VDC, 6-15 mA Action OFF→ON 3 V level ON→OFF 1 V Maximum input 200 kHz 20 kHz frequency Input impedance 4.7 kΩ Input signal Signal signal: 5 – 24 VDC (sinking or sourcing) ; differential signal: 5 V Electrical input 500VDC isolation Input display When the optocoupler is driven, the input LED indicator is ON.
Weight 138 g Model SSI input SSI output Item Number of inputs / 2 (DATA+/DATA-) 2 (CLK+/CLK-) outputs Connector type D-sub 15 Voltage / Current 5 VDC, 1 mA 5 VDC, ±60 mA (max.) Action OFF→ON VID*1 ≧ 0.2V - level ON→OFF VID ≦ 0.2V - Maximum input 1.25 MHz frequency Input impedance 12 kΩ (terminal resistor 120 Ω) - Input signal RS-422 Electrical 500VDC input/output isolation Input display When the optocoupler is driven, the input LED indicator is ON.