NIC1 : Indicates network activity on GLAN1 when flashing. ! Power Failure: When flashing, indicates a failure of the power supply Information LED : Alerts operator of several states, as noted in the table below. Overheating There are several possible responses if the system overheats. Overheat Temperature Setting Some backplanes allow the overheat temperature to be set at 45, 50, or 55 degrees by changing a jumper setting. For more information, consult the backplane user manual at www.supermicro.com. (Click Support > Manuals .) Responses If the server overheats: 1. Use the LEDs to determine the nature of the overheating condition. 2. Confirm that the chassis covers are installed properly.
4-3 Information LED Status Description Continuously on and red An overheat condition has occured. (This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan. Blinking red (0.25Hz) Power failure, check for a non-operational power supply. Solid blue Local UID has been activated. Use this function to locate the server in a rack mount environment. Blinking blue Remote UID is on. Use this function to identify the server from a remote location.