SC523 Chassis Manual Chapter 6: Rack Installation L-Brackets L-Brackets 1 3 Figure 6-6. Mounting the Chassis onto an Open (Telco) Rack Installing the chassis into a Telco type rack Installing the Server into a Telco Rack 1. Use two L-brackets on either side of the chassis (four total). Determine how far the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between the front and back of the rack. If a bezel is included on your chassis, remove it. Figure 6-5. Mounting the Chassis onto the Rack 2.
Attach the two front brackets to each side of the chassis, and then add the two rear brackets, positioning them with just enough space to accommodate the width of the rack. 3. When the server has been pushed completely into the rack, you should hear the locking tabs "click" into the locked position. 4. (Optional) Insert and tightening the thumbscrews that hold the front of the server to the rack. 3. Complete the installation by sliding the chassis into the rack and tightening the brackets. Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing.