Super Micro Computer, Inc. SC811 — Super Micro SC811 Chassis Manual PDF Download

SC811 Chassis Manual 3-2 Control Panel Buttons There are two push-buttons located on the front of the chassis. These are (from left to right) a reset button and a power on/off button. Reset: The reset button is used to reboot the system. Power: The main power switch is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied to the system. Therefore, you must unplug system before servicing. 3-3 Control Panel LEDs The control panel located on the front of the SC811 chassis has five LEDs. They provide you with critical information related to different parts of the system.

This sec­ tion explains what each LED indicates when illuminated and any corrective action. Information LED : Alerts operator of several states, as noted in the table below. 3-2 Informational LED Status Description Continuously on and red An overheat condition has occured. (This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan. Blinking red (0.25Hz) Power failure, check for a non-operational power supply. Solid blue Local UID has been activated. Use this function to locate the server in a rack mount environment. Blinking blue Remote UID is on. Use this function to identify the server from a remote location.