SC836 Chassis Manual #4. Fan Connectors The 4-pin connectors, designated JP54, JP56, JP58 and JP60, provide power to the fans. See the table on the right for pin definitions. These 4-pin connectors are compatible with 3-pin and 4-pin fans. #5., #6., #7., #8. I 2 C Y-Cable Connectors The I 2 C Y-cable connectors, designated JP37, JP52, JP95, and JP96, are for enclosure management of the I 2 C mode connection. These connectors are used only if the I 2 C is not embedded into the sideband connectors. See the table on the right for pin definitions. #9. Backplane Main Power Connectors The 4-pin connectors, designated JP10, JP13, JP46, and JP48, provide power to the backplane.
See the table on the right for pin definitions. All four of these connectors must be used at the same time. #10., #11., #12., #13. Sideband Headers The sideband headers are designated JP66, JP68, JP75 and JP77. are for enclosure management of the SGPIO mode connection. See the table to the right for pin definitions. C-12 Fan Connectors Pin# Definition 1 Ground 2 +12V 3 Tachometer 4 No connection I2C Y-Cable Connector Pin Definitions Pin# Definition 1 Data 2 Ground 3 Clock 4 No Connection Backplane Main Power 4-Pin Connector Pin# Definition 1 +12V 2 and 3 Ground 4 +5V Sideband Headers Pin # Definition Pin # Definition 2 SGPIO: SDIN I2C:
Backplane Addressing (SB5) 1 Controller ID (SB6) 4 SGPIO: SDOUT I2C: Reset (SB4) 3 GND (SB2) 6 GND (SB3) 5 SGPIO: SLOAD I2C:SDA (SB1) 8 Backplane ID (SB7) 7 SGPIO: SCLOCK I2C:SCL (SB0) 10 No Connec- tion 9 No Connection