Supermicro SC936E16-R1200B — Supermicro SC936E16-R1200B Chassis Manual: 3U Server with Hot-Swappable Drives

Chapter 4: Chassis Setup and Maintenance 4-6 Installing the Air Shroud Air Shroud Extension Rear Fans Figure 4-6: Air Shroud for SC936 Chassis Air shrouds concentrate airflow to maximize fan efficiency. The SC936 chassis air shroud is designed to fit within the chassis, and does not require tools for setup. Installing the Air Shroud 1. Power down the system, remove the power cord from the rear of the power supply and remove the chassis cover as described in Section 4-1. 2. If necessary, remove the rear fan by pressing the fan release tab and pulling the fan from the chassis. 3. Move the cables from the power supply and power distributor to the bottom of the chassis.

You may have to bind the cables together. 4. Slide the air shroud extension into the groove behind the fan closest to the power supply. The extension should almost touch the side of the chassis. 5. Slide the air shroud into the chassis. The air shroud connects to the air shroud extension, the two front fans, and two rear fans. 6. The air shroud includes perforations on the bottom. These perforations can be removed if motherboard components interfere with the air shroud placement. Do not remove more perforations than necessary. 7. Install the rear fans by sliding each fan into the fan housing on the chassis. 4-7 Air Shroud R F