Supermicro SC936E16-R1200B — Supermicro SC936E16-R1200B Chassis Manual: 3U Server with Hot-Swappable Drives

SC936 Chassis Manual Figure 4-10: Changing the Power Distributor Server chassis that are 2U or higher require a power distributor. The power distribu­ tor provides failover and power supply redundancy. In the unlikely event you must change the power distributor, do following: Changing the Power Distributor 1. Power down the system, remove the power cord from the rear of the power supply and remove the chassis cover as described in Section 4-1. 2. Remove all cable connections to the power supply from the motherboard, backplane, and other components. Also, remove both power supplies. 3. Locate the power distributor between the power supply and the fan row. 4.

Remove the three screws securing the power supply. 5. Gently pull the power distributor from the chassis. Gently guide all the cables through the power distributor housing. 6. Slide the new power distributor module into the power distributor housing. Make that you slide the cables through the bottom of the housing. 7. Reconnect all the power cables, replace the power supply, plug the power cord into the rear of the power supply and power up the system. 4-12