No limits for each mode switch. While motor running, speed control, position control or torque control can be switched to internal setting speed control. Speed 3 Deceleration stop ( Pn 311 ) Speed 2 Speed 1 / COIN Command pulse / SPD - A / SPD - B OFF ON ON OFF OFF OFF ON ON OFF OFF OFF ON Command Speed 1 Speed2 Speed 3 Switching Pulse Speed Internal 1 Mode Internal speed mode Position mode Speed mode Note : The internal speed mode is decelerated during the deceleration time set by Pn311 to stop the motor, then switch to the position mode .
b) Digital input signal distribution mode is parameter configuration (Pn600=1 default parameter) Through the ON/OFF switching control mode of the control mode switching (/C-SEL) signal, the signal is not configured in the factory default Digital input configuration. Therefore, the pin number configuration of the function is performed by parameters Pn601 ~ Pn609 (0x0B). 105 SD700 Series Servo Technical Manual ON ON Internal speed 2 (Pn305) ON OFF Internal speed 3 (Pn306) ON OFF OFF Second mode determines Analog speed mode Position mode Torque mode OFF ON Negative Internal speed 1 (Pn304) ON ON Internal speed 2 (Pn305) ON OFF Internal speed 3 (Pn306)