5.7 Timing Sequence 5.7.1 Power Enable ON Timing sequence Main circuit power up Main power Control power Control circuit power up 2 s CPU status initialization normal operation Servo preparation (/S-RDY) valid Servo enable (/S-ON) valid PWM output Servo output 1 Electromagnetic brake (/ BK ) Release brake torque command input Position/ speed/ Command input valid 1: There is a delay in the electromagnetic brake operation. The operation time varies depending on the type of brake . It is recommended to be more than 100ms to ensure that the electromagnetic brake is completely released when the command is input. This time can be omitted when motor is not braked . .

109 SD700 Series Servo Technical Manual invalid invalid Servo no output Action time Motor holding brake Invalid command input