5.7.2 Power-Off Enable OFF Timing Sequence Main power Control power PWM output torque command input Position/ Speed/ Release Motor holding Brake chain signal output brake brake (/BK) Release brake 1. Undervoltage fault occurs when the control power supply voltage drops below 170V/350V (220V series, 400V series.) . 2. Output from /BK to the actual brake of the motor. The time varies depending on the type of the brake. See “ Electromagnetic brake” for the timing of the /BK signal when the alarm or enable is OFF. 3. For the vertical axis, when the enable is ON, the power is off, the motor brake may not be completed, and the machine may move.

5.8 Full Closed Loop Control 5.8.1 What Is a Fully Closed Loop System The full closed-loop system is a system that uses external position feedback device (external encoder or grating ruler, etc.) to detect the actual machine position of the controlled object and feed back the actual machine position information to the servo unit. Because the actual machine position is directly fed back to the driver, high-precision positioning control can be realized. The full closed-loop servo system can eliminate the error caused by mechanical transmission mechanism, while the semi closed-loop servo system can only compensate part of the error.

Therefore, the accuracy of the semi-closed-loop servo system is lower than that of the full closed- loop system. Because of the position detection device, the position control accuracy of the closed- loop feed system mainly depends on the resolution and accuracy of the detection device (grating ruler, etc.) after other factors are determined. The structure of the full closed-loop and semi closed-loop servo system is more complicated than 110 SD700 Series Servo Technical Manual Main circuit power off *1 Control circuit power off *3 Servo output Servo no output invalid *2