VEICHI — SD700 User Manual 20230516

that of the open-loop feed system because of the position detection device. In addition, because the mechanical transmission mechanism is partially or completely included in the system, the natural frequency, damping and clearance of the mechanical transmission mechanism will become unstable factors of the system. Therefore, the design and debugging of the closed-loop and semi closed-loop systems are more difficult than those of the open-loop systems. The system structure is as follows: ! 1.

The gain adjusted in the semi closed loop mode may not be applicable in the full closed loop mode, so after the completion of adjustment in the semi closed loop mode switch to the fully closed loop mode need to re-optimize the gain parameters, so that the machinery and equipment to achieve good operating conditions. 2. To use the full closed loop function must first make the system in the semi closed loop mode to run normally before switching to full closed loop mode for commissioning.

Cautions 5.8.2 Parameter Setting of Full Closed-Loop Control 111 SD700 Series Servo Technical Manual Parameters Setting content Position Speed Torque Chapter control control control Pn002 Motor rotation direction selection ○ ○ ○ 3.2 Pn250 Application of external encoder in full closed loop control ○ ○ ○ 3.2 Pn253 Resolution of external grating ruler ○ ○ ○ 3.3 Pn204/ Pn206 Electronic gear ratio numerator / denominator ○ ─ ─ 3.5 Pn252 The deviation coefficient between the load of the motor with one full closed-loop rotation ○ ─ ─ 3.6