VEICHI — SD700 User Manual 20230516

5.8.3 Control Block Diagram of Full Closed Loop Control 5.8.4 Setting of Motor Rotation Direction And Machine Moving Direction When setting motor rotation direction and machine moving direction for full closed-loop control, pn002 (rotation direction selection) and PN250 (use method of external encoder in full closed-loop control) must be set at the same time. • The frequency division pulse is independent of the setting of pn002, and becomes B-phase lead for forward rotation command. • FWD direction: the direction in which the pulse count is positive. • REV direction: pulse counting is the direction of counting down.

112 SD700 Series Servo Technical Manual Pn257 Setting of excessive deviation between motor and load ○ ─ ─ 3.6 Parameter Pn250 Application of external encoder in full closed loop control 1 3 Pn002 (Motor rotation direction) 0 Command direction FWD command Reverse command FWD command Reverse command Motor rotation direction CCW CW CCW CW External encoder FWD move REV move REV move FWD move 1 Command direction FWD command Reverse command FWD command Reverse command Motor rotation direction CW CCW CW CCW External encoder REV move FWD move FWD move REV move