Related parameters ◆ Pn002 Motor rotation direction selection Facing the motor end face:0 - Counter-clockwise direction is FWD, 1 - Clockwise direction is FWD. ◆ Pn250 Application of external encoder in full closed loop control Set Pn250 =1 or Pn250 =3 in full closed-loop control. Supplementary notes: please confirm the setting value of PN250 according to the following points: (1) Set PN250 = 1, which is used in the standard running direction. (2) Manually rotate the motor shaft along the CCW direction.

(3) When the full closed-loop feedback pulse counter counts positively (Un012), or the servo monitoring parameter Un007 (feedback pulse counter) and Un012 (external encoder feedback pulse counter) change in the same direction, the setting of PN250 remains (4) When the full closed loop feedback pulse counter counts down, or if the servo monitoring unchanged (Pn250 = 1). parameter Un007(feedback pulse counter) and Un012 (external encoder feedback pulse counter) change in different directions, Pn250 = 3. 5.8.5 Resolution of External Grating Ruler Through pn253, the pitch value of the external encoder grating ruler is set by pn253, which is also called the resolution of grating ruler.

For example: [parameters] Pitch of grating ruler of external encoder: 0.5μM. Ball screw lead: 16mm. If the motor is not directly connected through the reduction mechanism. Then 16mm / 0.0005mm = 32000, so the setting value is “32000”. 113 SD700 Series Servo Technical Manual Parameters Name Definition Effect time Variety Pn250 0 (default) Application of external encoder in full closed loop control Not use full closed-loop control After restart Set 1 Use in standard running direction 2 Backup 3 Use in reverse running direction