Full closed-loop mode: 5.8.8 Setting of alarm detection 5.8.8 Setting of alarm detection 5.8.8 Setting of alarm detection The alarm detection settings (Pn252, Pn257) are shown below. The setting of detection value excessive deviation between motor and load position (pn257) is the difference between motor encoder feedback (position) and full closed-loop external encoder feedback (load position). If the set value is exceeded, output=Er.d10 (alarm of excessive deviation between motor and load position). (Note) when set to “0”, Er.d 10 is not output. Setting of deviation coefficient (Pn252) between motor loads when full closed-loop rotation 1 turn.
Set the “coefficient of deviation between motor and external encoder” when the motor rotates for 1 turn. It can be used to prevent out of control caused by damage of external encoder, or to detect “sliding” in belt mechanism. ◆ Setting Case When the sliding rate of the belt is large or seriously twisted, please increase the value.
117 SD700 Series Servo Technical Manual Steps Contents Mechanical composition 1 Grating resolution of linear encoder 0.0005mm(0.5µ m) 2 Command unit 0.0005mm(0.5µ m) 3 Electronic gear ratio = = 4 5.8 Seting o Parameter f alrm detcion 5.8 Seting of alrm detcion Pn204=1, Pn206=1 Pn257 Detection value of excessive deviation between motor and load position (Postion mode). Setting range Setting unit Default Effective time Variety 0 ~ 1073741824 1 Command unit 1000 Immediately Setting