VEICHI — SD700 User Manual 20230516

The torque limit function is about calculate the torque that mechanical motions need in order to make sure that the torque is not greater than this troque limit value. If the torque is set below the value required for operation, overshoot or vibration may occur. 2) The settings of the torque limit See more details in the “torque limit”. 3) Set excessive position deviation alarm value The excessive position deviation alarm is an effective protection function when we are using servo unit for position control. When the motor operation does not match the command, you can detect the abnormal condition and stop the motor by setting an appropriate position deviation alarm.

The position deviation is the difference between the position command value and the actual position. The position deviation can be expressed by the relationship between the following position loop gain (Pn103) and motor speed. When the acceleration/deceleration of the position command exceeds the tracking ability of the motor, the follow-up hysteresis will become large, resulting in the positional deviation not satisfying the above relation. Please reduce the acceleration and deceleration of the position command to the value that can be tracked by the motor or increase the value of the excessive position error alarm.

4) Set the vibration detection function Please initialize (Fn105) the detection value detected by the vibration and set an appropriate value for the vibration detection function. For details, refer to the corresponding “Accessibility”. 5) Set excessive position deviation alarm value when servo is ON If the servo is turned ON while the position deviation is accumulated, the motor will return to the original position to make the position deviation “0”and avoid causing a danger. In order to avoid this kind of situation, you can set an excessive position deviation alarm value when the servo is turned on to restrict the operation.

6.2 Robust Control In factory default, the robust control function is valid. When resonance and vibration occur, please change the attune value and load value via Fn301 or set Pn177 and Pn178. 6.2.1 Summary Robust function could get stable response through adjusting the whole system automatically no matter what kind of mechanism or fluctuation of load. 121 SD700 Series Servo Technical Manual Function Parameter Range Default Unit Communication When code address enabled