7 Auxiliary Functions 7.1 List of Auxiliary Functions The auxiliary functions are used to execute the functions related to the operation and adjustment of the servo motor. Each auxiliary function has a number starting with Fn. The following table lists the auxiliary functions and reference items. 7.2 Alarm Records Display (Fn000) 7.2.1 Overview The alarm record function can record up to 10 alarms that have occurred in the servo unit. You can confirm the alarm code and time that occurs.
(measurement of the duration of the control power supply and the main circuit power supply in 100ms increments, and the function to display the total operation time in the event of an alarm, It can be measured continuously for about 31 years if it is operated 24 hours per day and 365 days per year). ! 1. When the same alarm occurs continuously, if the interval between alarms is less than 1 hour, it will not be saved, and if it exceeds 1 hour, all will be saved. 2. When no alarm occurs, “ - - -” is displayed on the panel operator. 3. The alarm record can only be cleared by “clear alarm record (Fn001)”.
Cautions 142 SD700 Series Servo Technical Manual Auxiliary function Code Function description Fn 000 Alarm record display Fn 001 Clear alarm record Fn 002 Software reset Fn 003 Restore factory parameters Fn 005 JOG operation Fn 006 Program JOG operation Fn 100 Automatic adjustment of command offset Fn 101 Speed command offset manual adjustment Fn 102 Torque command offset manual adjustment Fn 103 Current offset automatic adjustment Fn 104 Current offset manual adjustment Fn 105 Initialize the detected value of the vibration detection Fn 303 Bandwidth setting Fn 401 Easy FFT Fn 402 Online vibration monitoring