7.15.2 Operating Procedure MODE/SET Amplitude UP/DOWN DATA/SHIFT Long press setting DATA/SHIFT Long press Any interface MODE/SET Auxiliary function UP EasyFFT DATA/SHIFT Long press Amplitude setting DATA/SHIFT Long press Ready state Flash2s Confirmation of results MODE/SET Checkout Checkout UP/DOWN Operating MODE/SET result Flash2s process status 7.16 Online Vibration Monitoring (Fn402) 7.16.1 Overview When the servo is ON and vibration occurs during operation, this operation can set the notch filter 1 or the torque command filter according to the vibration frequency, sometimes eliminating the vibration.
Detect the vibration frequency of noise caused by mechanical resonance and display the vibration frequency with large peak on the operator. The effective torque command filter or notch filter 1 frequency for the vibration frequency will be automatically selected and the related parameters are automatically set. When using the PC debugging software to adjust, it is recommended to perform the smart setting or bandwidth setting. Generally, no manual operation is required. Only when the PC debugging software is not available, it is key-assisted.
7.16.2 Operating Procedure Long press DATA/SHIFT Long press Monitoring failed DATA/SHIFT Any interface MODE/SET Auxiliary function UP monitoring Vibration DATA/SHIFT Long press preparation Monitoring MODE/SET V phase offset manual adjustment DATA/SHIFT Long press C onfirm MODE/SET Monitoring results 152 SD700 Series Servo Technical Manual