VEICHI — SD700 User Manual 20230516

As shown in the figure above, section C of Pn800 is defined as home position return automatically trigger when power on. When the C segment is set to 1, it performs the home position return automatically when the servo is enabled for the first time. The A and B sections of Pn800 are defined as the point number for automatic operation after the home position return is completed. 8.1.4 Home Position Return Triggered By Point Function The home position return function can be triggered by the point function. The definitions of SI terminals related to point functions are shown in Table 2.3 below:

Table 2.3 SI terminal point function definition As shown in the above table, the point function is triggered by the external terminals. If the point segment number selection value is 0 when triggering, the home position return operation will be triggered. That is, when the rising edge of the PosTrig signal is valid, if the point segment number selection combination value is 0 (PosBit0 to PosBit4 are all 0), the home position return operation is triggered. 8.1.5 Communication Triggers Home Position Return In addition to triggering the home return operation with the SI terminal, the home position return can also be triggered by communication.

Through serial port communication, USB communication, keyboard operation, etc., the home position return operation is triggered in the case of writing 0 to the function code Pn898. Pn898 displays 10000 during the home position return process, and Pn898 displays 20000 after the home position return is completed. Note: The home position return trigger is valid only when the servo drive is enabled. If the servo is not enabled, the home position return is invalid. 8.2 Home Position Return Function Code Parameter description:

Home position return mode, any integer value between 1 and 34 can be 156 SD700 Series Servo Technical Manual SI Terminal SI Terminal Function Code Function Description Name PosTrig 0x16 Point trigger function (valid on rising edge) PosBit0 0x17 Point segment number selection Bit0 (valid at high level) PosBit1 0x18 Point segment number selection Bit1 (valid at high level) PosBit2 0x19 Point segment number selection Bit2 (valid at high level) PosBit3 0x1A Point segment number selection Bit3 (valid at high level) PosBit4 0x1B Point segment number selection Bit4 (valid at high level) Pn899 Home position return method selection ○ Address:0x899 Factory default:1 Setting range:1~34 unit:

N/A Control mode: P