8.3.13 Home Position Return Method 13 a.Start the home position return →Home position signal OFF →Search for the falling edge of home position at high speed reverse direction →Decelerate to 0 →Search for the rising edge of home position at low speed forward direction →Search for the Z pulse in forward direction. Forward direction 13-a Z pulse Home position return method 13-a b.Start the home position return →Home position signal ON →Search for the falling edge of home position at high speed reverse direction →Decelerate to 0 →Search for the rising edge of home position at low speed forward direction →Search for the Z pulse in forward direction.
13-b Forward direction Z pulse Home position return method 13-b 175 SD700 Series Servo Technical Manual -H Running route L H Home sig Lim imit signal -H Running route L H Home p sig Z Limi