VEICHI — SD700 User Manual 20230516

c.Start the home position return →Home position signal OFF →Search for the falling edge of home position at high speed reverse direction →Touch the reverse limit →Search for the rising edge of home position at high speed forward direction →Decelerate to 0 →Search for the falling edge of home position at low speed reverse direction →Search for the rising edge of home position at low speed forward direction →Search for the Z pulse in forward direction.

13-c Forward direction Z pulse Home position return method 13-c 8.3.14 Home Position Return Method 14 a.Start the home position return →Home position signal OFF →Search for the falling edge of home position at high speed reverse direction →Decelerate to 0 →Search for the rising edge of home position at low speed forward direction →Search for the falling edge of home position at low speed reverse direction →Search for the Z pulse in reverse direction. 14-a Forward direction Z pulse Home position return method 14-a 176 SD700 Series Servo Technical Manual Limit signal Motor Home position signal -H Running route H L Limit signal Home position Motor signal L -H