Same as Pn888 Same as Pn888 Same as Pn888 Same as Pn888 Same as Pn888 Same as Pn888 Parameter description: Internal multi-segment position command delay time selection. From the function code Pn890 to Pn897, a total of 8 sets of internal multi-segment position delay time selection are provided. When the internal multi-segment position control is actually performed, a set of parameters between Pn890 and Pn897 is selected as the internal multi-segment position between the two-point position command according to the value of the D portion of the internal multi-segment position control word high 16 bits. Interval time (unit: 0.1s, delay time range is 0s ~ 6000s).
211 SD700 Series Servo Technical Manual Default: 500 Setting range: 0 ~ 6000 Unit: rpm Control mode: P Pn88B Internal multi-segment position speed value selection 3 ○ Communication address: 0x88B Default: 1000 Setting range: 0 ~ 6000 Unit: rpm Control mode: P Pn88C Internal multi-segment position speed value selection 4 ○ Communication address : 0x88C Default: 1500 Setting range: 0 ~ 6000 Unit: rpm Control mode: P Pn88D Internal multi-segment position speed value selection 5 ○ Communication address: 0x88D Default: 2000 Setting range: 0 ~ 6000 Unit: rpm Control mode: P Pn88E Internal multi-segment position speed value selection 6 ○ Communication address: 0x88E Default: 2500 Setting range:
0 ~ 6000 Unit: rpm Control mode: P Pn88F Internal multi-segment position speed value selection 7 ○ Communication address: 0x88F Factory value: Setting range: 0 ~ 6000 Unit: rpm Control mode: P 3000 Pn890 Internal multi-segment position delay time selection 0 ○ Communication address: 0x890 Default: 0 Setting range: 0 ~ 60000 Unit: 0.1s Control mode: P