VEICHI — SD700 User Manual 20230516

Note: For the position command, the delay time is the calculated after the position command pulse is sent. For the speed mode, the delay time is calculated after the speed value reaches the set target speed. Same as Pn890. Same as Pn890. Same as Pn890. Same as Pn890. Same as Pn890. Same as Pn890. Same as Pn890. 212 SD700 Series Servo Technical Manual Pn891 Internal multi-segment position delay time selection 1 ○ Communication address: 0x891 Default: 1 Setting range: 0 ~ 60000 Unit: 0.1s Control mode: P Pn892 Internal multi-segment position delay time selection 2 ○ Communication address : 0x892 Default: 5 Setting range: 0 ~ 60000 Unit: 0.1s Control mode:

P Pn893 Internal multi-segment position delay time selection 3 ○ Communication address: 0x893 Default: 10 Setting range: 0 ~ 60000 Unit: 0.1s Control mode: P Pn894 Internal multi-segment position delay time selection 4 ○ Communication address: 0x894 Default : 100 Setting range : 0 ~ 60000 Unit: 0.1s Control mode: P Pn895 Internal multi-segment position delay time selection 5 ○ Communication address: 0x895 Default: 1000 Setting range: 0 ~ 60000 Unit: 0.1s Control mode: P Pn896 Internal multi-segment position delay time selection 6 ○ Communication address: 0x896 Factory value: 5000 Setting range: 0 ~ 60000 Unit: 0.1s Control mode:

P Pn897 Internal multi-segment position delay time selection 7 ○ Communication address: 0x897 Default: 10000 Setting range: 0 ~ 60000 Unit : 0.1s Control mode: P