VEICHI — SD700 User Manual 20230516

9.8 Jog Function The jog function can realized by means of communication or internal jog operation via external terminals. The jog function must be operated when the servo is enabled. In the process of jog execution, the point function is no longer executed. The point can be executed normally after the jog execution is completed. The internal jog function code is shown in the following table: Parameter description: Jog speed setting. Unit rpm Parameter description: In jog mode, acceleration and deceleration time setting. Parameter description: After the point reaches the set speed, the delay time. 224 SD700 Series Servo Technical Manual Pn500 Jog speed ○ Communication address: 0x500 Default:

500 Setting range: 0~1000 Unit: rpm Control mode: P,S Pn505 Jog acceleration and deceleration time ○ Communication address: 0x505 Default: 100 Setting range:2~10000 Unit: ms Control mode: P,S Pn506 Jog delay time ○ Communication address: 0x505 Default: 100 Setting range: 0~10000 Unit: ms Control mode: P,S