VEICHI — SD700 User Manual 20230516

10.4 Pn3 Group Speed Related Parameters 243 SD700 Series Servo Technical Manual Function Parameter Range Default Unit Communication When code address enabled Pn300 Analog speed command gain 150~3000 600 0.01V/ rated speed 0x0300 Immediately Use this parameter to set the analog voltage value of (V-REF) when the speed of servo motor is rated speed. Note: do not apply a voltage above - 10 ~ 10V. Exceeding this range may cause damage to the drive. Pn301 Reversed analog 0~1 0 - 0x0301 Immediately speed command Set the voltage polarity of the analog speed command: 0- Positive polarity: positive voltage corresponds to positive speed command. 1- Negative polarity:

positive voltage corresponds to negative speed command. Pn302 Analog speed 0~655.35 0.40 ms 0x0302 Immediately instruction filter time The function could be set to smooth the speed command when one delay filter is applied to the analog speed command (V-REF) input and it does not usually need to be changed. If the set value is too large, the responsiveness may decrease. Please set this parameter while confirming the response. Pn303 Analog speed 0~3 0 V 0x0303 Immediately command dead zone range In the analog speed control, even if the input command is 0V, the servo motor may rotate at a slight speed. This is because there is a slight deviation in the commands inside the servo unit.

This error can be eliminated by setting an appropriate analog speed command deadband range. Pn304 Pn305 Pn306 Internal speed 1 0~10000 100 rpm 0x0304 Immediately Internal speed 2 0~10000 200 rpm 0x0305 Immediately Internal speed 3 0~10000 300 rpm 0x0306 Immediately When operating in the internal speed mode, the servo unit provides three internal speed commands and through Switch Internal Speed Command Selection A and B we could select as follow:

/SPD-A /SPD-B Speed Command OFF OFF Zero Speed OFF ON Internal speed 1 ON ON Internal speed 2 ON OFF Internal speed 3 Pn310 Speed command trapezoidal acceleration time 0~30000 0 ms 0x0310 Immediately Acceleration of the set speed from 0r/min to the rated speed (corresponding to the motor model). When the given speed is greater or less than the rated speed, the actual acceleration time is calculated in proportion. Pn311 Speed command trapezoidal deceleration time 0~30000 0 ms 0x0311 Immediately Acceleration time of the set speed from to the rated speed (corresponding to the motor model) to 0r/min.

When the given speed is greater or less than the rated speed, the actual acceleration time is calculated in proportion.