VEICHI — SD700 User Manual 20230516

245 SD700 Series Servo Technical Manual The parameter is used to smooth the torque command when we apply 1 delay filter to the analog torque command (T-REF) input, usually it does not need to be changed. If the set value is too large, the responsiveness may decrease. So please set it up as we check the response. Pn405 Analog torque command gain 10~100 30 0.1V/ Rated torque 0x0405 Immediately This parameter is used to set the analog (T-REF) voltage value which corresponds the rated torque of the servo motor. Caution: Do not apply more than -10V~10V, exceeding this range may cause damage to the driver.

Pn406 Reversed analog torque command 0~1 0 - 0x0406 Immediately The analog voltage corresponds to the polarity setting of the torque command: 0-Positive polarity: Positive voltage corresponds to positive torque command. 1-Negative polarity: Positive voltage corresponds to negative torque command. Pn407 Analog torque command dead zone range 0~3 0 V 0x0407 Immediately In analog torque control, even if the input command is 0V, the servo motor may rotate at a slight speed. This is because a slight deviation occurs in the command inside the servo unit. This error can be eliminated by setting an appropriate analog torque command deadband range.

Pn410 Internal torque command in torque control -500~500 0 % 0x0410 Immediately Select the torque command setting when the command source of torque control is internal setting. Pn411 Speed limit mode setting during torque control 0~1 1 - 0x0411 After restart 0-The smaller value between the speed corresponding to the analog voltage (V-ref) and the speed set by Pn413. 1-The speed set by Pn413. Pn412 Speed limit selection 0x00~0x01 0 - 0x0412 After restart 0- Motor maximum speed (determined by internal part of the motor model) + torque mode speed limit (Pn411). 1- Overspeed detection alarm speed (determined by internal part of the motor model) + torque mode speed limit (Pn411).

Pn413 Speed limit in torque control 0~10000 1000 rpm 0x0413 Immediately This parameter is used to set speed limit in torque control with Pn411. Pn415 Internal torque control command smooth acceleration time 0~30000 100 ms 0x0415 Immediately Set the internal torque control command smooth acceleration time. Pn416 Internal torque control command smooth deceleration time 0~30000 100 ms 0x0416 Immediately Set the internal torque control command smooth deceleration time. Pn420 Target torque reaching value setting 0.0~500.0 100 - 0x0420 Immediately