10.6 Pn5 JOG Related Parameters 10.7 Pn6 Group Switch Configuration Related Parameters 246 SD700 Series Servo Technical Manual Set the target torque reaching value. Pn421 Target torque reaching time window 0~1000 5 ms 0x0422 Immediately Set target torque reaching time window. Function Parameter Range Default Unit Communication When enabled code address Pn500 JOG speed 0~1000 500 rpm 0x0500 Immediately Pn502 Program JOG operation mode 0x00~0x05 0 - 0x0502 Immediately 0-(waiting time->forward running)*number of cycles. 1-(waiting time->backward running)*number of cycles. 2-(waiting time->forward running)*number of cycles->(waiting time->backward running)*number of cycles.
3-(waiting time->backward running)*number of cycles->(waiting time->forward running)*number of cycles. 4-(waiting time->forward running->waiting time->backward running)*number of cycles. 5-(waiting time->backward running->waiting time ->forward running)*number of cycles. Pn503 Program JOG running distance 1~ 1073741824 32768 command unit 0x0503 Immediately Set the JOG movement distance of the running program as the command unit. Pn505 Program JOG acceleration/ deceleration time 2~10000 100 ms 0x0505 Immediately Set the time of accelerating from 0r/min to the rated speed (corresponding to the motor model).
When the set speed is greater or less than the rated speed, calculate the actual acceleration/deceleration time according to the ratio. Pn506 Program JOG waiting time 0~10000 100 ms 0x0506 Immediately Set the waiting time between JOG sections of the running program in conjunction with the program JOG operation mode (Pn502). Pn507 Program JOG movement times 0~1000 1 circle 0x0507 Immediately Set the movement times of the running program in conjunction with JOG operation mode (Pn502) Note: it is infinite when set to 0.
Pn508 Program JOG movement speed 1~10000 500 rpm 0x0508 Immediately Function Parameter Range Default Unit Communication When code address enabled Pn600 Switching value input signal distribution mode 0~1 1 - 0x0600 After restart