247 SD700 Series Servo Technical Manual Set switching value input signal distribution mode: 0-Internal fixed: used by pins and functions are fixed inside by servo unit. See “CN1 terminal” for details. 1-Parameter configuration: It is used according to the function configured on each pin and is configured and used by function code Pn601~Pn609.

Pn601 Pn602 Pn603 Pn604 Pn605 Pn606 Pn607 Pn608 Pn609 CN1-40 input configuration 0~0x114 0x01 - 0x0601 After restart CN1-42 input configuration 0~0x114 0x02 - 0x0602 After restart CN1-43 input configuration 0~0x114 0x03 - 0x0603 After restart CN1-41 input configuration 0~0x114 0x05 - 0x0604 After restart CN1-44 input configuration 0~0x114 0x04 - 0x0605 After restart CN1-45 input configuration 0~0x114 0x06 - 0x0606 After restart CN1-46 input configuration 0~0x114 0x07 - 0x0607 After restart CN1-39 input configuration 0~0x114 0x00 - 0x0608 After restart CN1-38 input configuration 0~0x114 0x00 - 0x0609 After restart 0x00: Invalid 0x01: Servo enable 0x101: Servo enable negation 0x02:

Run in positive direction 0x102: Positive direction is prohibited 0x03: Run in negative direction 0x103: Negative direction is prohibited 0x04: Alarm clear 0x104: Alarm clear negation 0x05:Manual P-PI control 0x105:Manual P-PI control negation 0x06: Torque limit switch 0x106: Torque limit switch negation 0x07: Reserved 0x107: Reserved 0x08: Internal speed command direction 0x108: Internal speed command direction selection selection negation 0x09: Internal speed command selection A 0x09: Internal speed command selection A 0x109: Internal speed command selection A negation 0x0A: Internal speed command selection 0x10A: Internal speed command selection B B negation 0x0B:

Control mode switch 0x10B: Control mode switch negation 0x0C: Zero speed clamp 0x10C: Zero speed clamp negation 0x0D: Command pulse inhibit 0x10D: Command pulse inhibit negation 0x0E: Gain switching 0x10E: Gain switching negation 0x0F: Direction selection of torque 0x10F: Direction selection of torque command command negation 0x10: Command pulse rate switching 0x10: Command pulse rate switching 0x110: Command pulse rate switch negation 0x12: Motor over temperature input 0x112:Motor over temperature input negation 0x16: Internal position command trigger 0x116: Internal position command triggers negation 0x17: Internal position instruction 0x117:

Internal position instruction selection bit0 selection bit0 negation 0x18: Internal position instruction 0x118: Internal position instruction selection bit1 selection bit1 negation 0x19: Internal position instruction 0x119: Internal position instruction selection bit2 selection bit2 negation