250 SD700 Series Servo Technical Manual Vibration detection level (rotation) in 0~5000 0 r/min 0x0705 Immediately Pn706 inertia identification Vibration detection level (rotation) setting in inertia identification. Function test selection without motor 0x00~0x01 0 - 0x0730 After restart The function test without motor is not to start the real motor, simulate the action of the motor in the servo unit, and confirm the action of the host device and peripheral equipment.
Through this function, wiring confirmation, parameter value verification and verification in case of system commissioning failure can be carried out, so as to shorten the set operation time and avoid mechanical damage caused by wrong action. When no motor test function is running, the motor action can be confirmed whether the motor is connected or not. 0-Invalid. 1-Valid. Pn730 Encoder resolution selection when no- motor test function 0~3 1 - 0x0731 After restart Pn731 When no-motor test mode is selected, the motor encoder resolution is set: 0-13 bits 1-17 bits 2-20 bits 3-23 bits Note: when the encoder is actually connected, the resolution of the actual encoder is used.
No-Motor test function encoder type selection 0x00~0x01 0 - 0x0732 After restart Pn732 Set no-motor test function encoder type: 0-Incremental encoder. 1-Absolute encoder. Absolute encoder operation 0~2 0 - 0x0792 After restart 0 - No action. 1 - Write motor parameters to encoder EEPROM. 2 - Clear multi-turn encoder circles: if you use it initially or replace or insert/remove the battery during power-down of the drive. After power on, an encoder backup alarm (Er. 810) will be reported. This parameter is set to 2 and it can only be cleared after re-powered. 3 - Only clear encoder alarm:
when the encoder gives an alarm (Er.810, Er.860,), set this parameter to 3 to clear the encoder alarm, but do not clear the multi turn value of the encoder, and keep the current position of the motor. Pn792 Zero offset of multi turn absolute encoder 0~2147483647 0 command unit 0x0792 After restart Pn798 Set zero offset of multi turn absolute encoder. Minimum software limit absolute position (32 bits) 2147483648~ 2147483647 2147483648 command unit 0x079A After restart Pn79A When the absolute position of the motor (Un021) is less than this position, the servo enters the limit alarm state.
Maximum software limit absolute position (32 bits) 2147483648~ 2147483647 2147483648 command unit 0x079C After restart Pn79C When the absolute position of the motor (Un021) is greater than this position, the servo enters the limit alarm state. Software limit absolute position switch 0~1 0 N/A 0x079E Immediately Pn79E 0: Close 1: Open