10.9 Pn8 Group Internal Position/Home Position Return Parameters 251 SD700 Series Servo Technical Manual Encoder overflow times -32768~32767 0 N/A 0x07A0 Immediately Pn7A0 Record the number of times the multi turn absolute encoder overflows. Percentage of motor locked rotor overload protection time 0~100 8 N/A 0x07A1 After restart Pn7A1 This parameter sets the time percentage of motor overload after locked rotor. If the setting is too large, the driver may be damaged. In order to protect the safety of the driver, please change this value under the guidance of the manufacturer's technical support.

Function Communication When Parameter Range Default Unit code address enabled Home position return 0~ 0x0 - 0x0800 Immediately Pn800 control word 0xFFFFFFFF Home position return control word mode setting, see Chapter 8 for details. - Zero position offset 2147483648 command 0 0x0802 Immediately Pn802 value ~ unit 2147483647 Set zero position offset position. 0~ Pr1 control word 0x0 - 0x0804 Immediately Pn804 0x80000000 Position setting of the first section,see Chapter 8 for details. Pr1 pulse number - 2147483648 ~ 2147483647 0 command unit 0x0806 Immediately Pn806 Set the position of the 1st segment. Pr2 control word 0~ 0x80000000 0x0 - 0x0808 Immediately Pn808 Same as Pn804.

Pr2 pulse number - 2147483648 ~ 2147483647 0 command unit 0x0810 After restart Pn80A Set the position of the 2nd segment. Pr3 control word 0~ 0x80000000 0x0 - 0x080C After restart Pn80C Same as Pn804. Pr3 pulse number - 2147483648 ~ 2147483647 0 command unit 0x080E Immediately Pn80E Set the position of the 3rd segment. Pr4 control word 0~ 0x80000000 0x0 - 0x0810 Immediately Pn810