252 SD700 Series Servo Technical Manual Same as Pn804. Pr4 pulse number - 2147483648 ~ 2147483647 0 command unit 0x0812 Immediately Pn812 Set the position of the 4th segment. Pr5 control word 0~ 0x80000000 0x0 - 0x0814 Immediately Pn814 Same as Pn804. Pr5 pulse number - 2147483648 ~ 2147483647 0 command unit 0x0816 Immediately Pn816 Set the position of the 5th segment. Pr6 control word 0~ 0x80000000 0x0 - 0x0818 Immediately Pn818 Same as Pn804. Pr6 pulse number - 2147483648 ~ 2147483647 0 command unit 0x081A Immediately Pn81A Set the position of the 6th segment. Pr7 control word 0~ 0x80000000 0x0 - 0x081C Immediately Pn81C Same as Pn804.
Pr7 pulse number - 2147483648 ~ 2147483647 0 command unit 0x081E Immediately Pn81E Set the position of the 7th segment. Pr8 control word 0~ 0x80000000 0x0 - 0x0820 Immediately Pn820 Same as Pn804. Pr8 pulse number - 2147483648 ~ 2147483647 0 command unit 0x0822 Immediately Pn822 Set the position of the 8th segment. Pr9 control word 0~ 0x80000000 0x0 - 0x0824 Immediately Pn824 Same as Pn804. Pr9 pulse number - 2147483648 ~ 2147483647 0 command unit 0x0826 Immediately Pn826 Set the position of the 9th segment. Pr10 control word 0~ 0x80000000 0x0 - 0x0828 Immediately Pn828 Same as Pn804.