265 SD700 Series Servo Technical Manual Er.730 DB overload 1 1. The load is too heavy when the machine stops that cause the overload of DB resistor and you could try to reduce the operating speed or reduce the load. 2. check whether the motor is driven by external force. 3. according to customer needs, re-evaluate whether it needs to pass the DB mode requirements during the shutdown, if you do not need, you can choose other ways to stop. 4. If the fault is reported in the last operation, run after waiting for a while after powering on. Category 1 Er.731 DB overload 2 1. Reduce the command speed of servo motor. 2. Reduce the moment of inertia ratio. 3. Servo driver problem, replace servo.
Category 1 Er.740 Inrush current limiting resistance fault 1. The servo driver is faulty. Replace the servo driver. Category 1 Er.7A0 Heat sink over- heat 1. Check whether the air duct is blocked and the fan is damaged with a fan drive. 2. Check the installation conditions of the driver, whether the heat dissipation condition is good or not and increase the heat dissipation condition of the driver as much as possible. 3. Check the drive load conditions, if the load is too heavy, you can suggest that customers replace a high-power segment of the drive. 4. If possible, reduce the driver carrier frequency. Category 2 Er.7AA Abnormal temperature of control board 1.
Improve the installation condition of servo driver and reduce the ambient temperature. 2. Reconfirm the load conditions and operation conditions. 3. Servo driver failure, replace the servo driver. Category 1 Er.7AB The fan inside the drive does not turn 1. Is there any foreign matter blocking the fan. 2. Servo driver failure, replace servo driver. Category 1 Er.810 Abnormal encoder backup 1. Check the multi-turn encoder battery power condition. 2. Perform multi-turn encoder clear operation. Category 1 Er.830 Battery under- voltage Replace multi-turn encoder battery. Category 1 Er.840 Encoder data is abnormal Encoder data is abnormal. Category 1 Er.850 Encoder overspeed Encoder overspeed.
Category 1 Er.860 Encoder temperature is high 1. Reduce the motor load rate. 2. Strengthen the heat dissipation effect of the motor. Category 1 Er.900 CANopen node protection failure 1. Check if the slave is offline. 2. Check whether the node protection time setting is correct. Category 1 Er.901 CANopen heartbeat detection timeout 1. Check if the host is offline. 2. Check whether the heartbeat detection time matches the host heartbeat production time. Category 1 Er.BF4 Hardware over-current Unplug the power cable and turn on the servo unit again. If an alarm still occurs, the servo unit may be malfunctioning, and then you could replace the servopack.
If not, confirm whether it is power line or motor failure. Category 1