12.2 Warning Code 266 SD700 Series Servo Technical Manual Er.C10 Out of control alarm 1. Check if the motor wiring is normal. 2. Check if the motor and encoder are normal. 3. Re-connect the servo drive power, if an alarm still occurs, it may be a servo drive failure. Category 1 Er.C90 Encoder communication failure: line- broken 1. Use multimeter to test every signal line of the encoder line and see if signal lines break. 2. Check the encoder line model and confirm the model is correct. 3. Check the length of the encoder line and the encoder line can not be too long. 4. It may be caused by interference, try to ground the driver or wire the encoder around the magnetic ring. 5.
check the motor group parameters and confirm the motor is correct. 6. If you already exclude various reasons and the servo driver may malfunction, then you could consider replacing the servo unit. Category 1 Er.C91 Abnormal encoder communication position data acceleration Category 1 Er.CA0 Abnormal encoder parameters Category 1 Er.D00 Excessive position deviation 1. Set the appropriate position deviation excessive alarm value. 2. Check whether the encoder cable and motor cable are connected properly. You can use the hand to rotate the motor and monitor whether the Un003 (rotor relative Z pulse position) varies between 0 and 16777216 (24-bit encoder). 3.
Calculate the pulse frequency input and acceleration planning and check if the electronic gear ratio setting is reasonable. 4. Determine whether the relevant parameters are reasonable. For example: you could check the torque limit, speed limit, inertia ratio, position gain, speed gain is too small or the position filter is too large, etc. 5. Calculate if the motor selection is too small or the acceleration and deceleration are too slow that cause huge position deviation. Category 1 Er.D01 Excessive position deviation during servo ON Set correct value of Pn267 (overrunning position deviation when servo is ON).
Category 1 Er.D02 Excessive position deviation alarm caused by speed limit during servo ON Set correct Maximum position deviation threshold (Pn264) or set correct speed limit value (Pn270) during servo ON. Category 2 Er.D10 Excessive deviation between motor and load position 1. Confirm the rotation direction of the motor and the installation direction of the external encoder. 2. Check the mechanical installation. 3. Set the parameter Pn250 to the correct value. Category 2 Warning Type Solutions code AL.900 Excessive Position deviation warning 1. Correctly set relevant parameters such as gear ratio, gain, position filtering, torque limit, etc. 2.
confirm the encoder line motor wiring is correct. 3. If you already exclude various reasons, the servo driver may malfunction and you could consider replacing the servo unit.