VEICHI — SD700 User Manual 20230516

In this mode, the message transmission starts at least at a pause interval of 3.5 characters. During transmission, the network device continuously detects the network bus, including the pause interval. When the first field (address field) is received, the corresponding device decodes the next transmitted character, and if there is a pause of at least 3.5 characters, it indicates the end of the message. In RTU mode, the entire message frame must be transmitted as a continuous stream. If there is a pause time of more than 1.5 characters before the frame is completed, the receiving device will refresh the incomplete message and assume that the next byte is the address of a new message. area.

Similarly, if a new message begins with the previous message in less than 3.5 character times, the receiving device will consider it a continuation of the previous message. If the above two situations occur during the transmission, the CRC check will inevitably generate an error message and feed back to the sender device. 13.4 Command Code and Communication Data Description In the communication command, the data address read and written is the hexadecimal number of the parameter name, for example, the address of the inertia ratio Pn100 is 0x0100. Function: Read N words (Word can read up to 16 words in succession). (1) Command code:

03H For example, if the servo drive with the slave address 01H reads the address e003 and reads two consecutive words, the structure of the frame is described as follows: Host command information: The slave responds to the message:

269 SD700 Series Servo Technical Manual Start bit Device address command data CRC check Terminator T1-T2-T3-T4 8Bit 8Bit N 8Bit 16Bit T1-T2-T3-T4 START T1-T2-T3-T4(3.5 bytes of transmission time) ADDR 01H CMD 03H Read start address high e0H Read start address low 03H high number of data (in word) 00H low number of data is (in word) 02H CRC CHK low bit 03H CRC CHK high bit CBH END T1-T2-T3-T4(3.5 bytes of transmission time) START T1-T2-T3-T4(3.5 bytes of transmission time) ADDR 01H CMD 03H Number of bytes 04H