c). From the above figure, you can analyze the frequency, amplitude, and phase of the resonance frequency. Click on [Settings] to set the frequency of the first notch filter. After the setting is completed, the screen is closed. Mechanical properties are completed. 14.5.5 FFT Analysis EasyFFT transfers the periodic waveform commands from the servo unit to the servo motor and rotates the servo motor slightly for a certain time to cause the vibration of the machine. The servo unit detects the resonance frequency based on the vibration generated by the machine, and then sets the corresponding notch filter according to the resonance frequency.
The notch filter effectively removes high-frequency vibrations and noise. Step: a). Click on to enter the FFT measurement interface. Set the command amplitude and rotation direction in the measurement conditions. Click to start measurement and you can measure the frequency of the first notch filter, as shown in the figure below: b). Click on [Start] to measure the first notch, and then click on [Write] to write the frequency of the first notch filter. c). Click on [Start] to measure the second notch, and then click on [Write] to write the second notch filter frequency. d). Click on [Next] → [Done] to close the operation interface and the FFT analysis is completed.
14.5.6 Bandwidth setting Bandwidth setting is the method of inputting a speed command or position command from the host device and manually adjusting it while it is running. By adjusting one or two values via bandwidth setting, the relevant servo gain settings can be automatically adjusted. 284 SD700 Series Servo Technical Manual