Bandwidth setting adjusts the following items. • Gain adjustment (speed loop gain, position loop gain, etc.). • Filter adjustment (torque command filter, notch filter). • IF suppression control. Step: a). Click of the main interface of the upper computer to enter the single parameter adjustment prompt interface, click on [Next] to enter the parameter adjustment interface, select the organization selection according to the actual situation, and select the desired mode, as shown in the following figure. b). Click on [Next] to enter the setting interface of inertia moment ratio and set the inertia ratio (inertia ratio can be obtained through inertia identification function). c).

Click on [Next] to enter the single parameter tuning interface as shown in the following figure. 285 SD700 Series Servo Technical Manual