d). Click on [Adjust Start] to tune the tuning value (generally increase). During the process of increasing the tuning value, the servo will vibrate. At this time, vibration detection will be performed automatically. If not, operation can be performed manually, and the tuning value can be set in combination with the figure captured by the digital oscilloscope, or 80% of the tuning value of the motor can be selected as the tuning value. Specific or combined with the actual site requirements for adjustment settings. e). In the tuning process, when the servo motor is vibrating, it will detect the resonance frequency and the intermediate frequency suppression frequency.
After the tuning is completed, click on [Next] to enter the auto tuning completion interface and click on [Finish] to complete the single parameter adjustment operation. 14.5.7 Offset Adjustment Offset adjustment is divided into two parts: 1: Speed/torque command offset (automatic/manual) adjustment. 2: Motor/current detection signal offset (automatic/manual) adjustment. Step: a). Click on the main interface of the host computer to enter the offset wizard interface. Click on [Next] to enter the offset adjustment function selection interface, select the function you need to adjust, and click on [Next] to enter the adjustment interface. b).
Set the adjustment method, click on [Next], click on [Finish], the offset adjustment screen closes, and the adjustment process ends. 14.5.8 Return to Origin The origin search is a function that determines the position of the origin pulse (Z phase) of the incremental encoder and stops at this position. 286 SD700 Series Servo Technical Manual