Step: a). Click on the main interface of the host computer to enter the origin setting wizard interface. Click [Next] to enter the execution instruction interface, as shown in the following figure. b). Click [Enable] to enable the servo motor to enter the enable state, and then click [Forward Run] or [Reverse Run] to perform the origin search. After the search is completed, click [Next] to enter the back to origin setting interface and click [Completed] to return to origin operation. 14.5.9 Soft Reset The function could reset the servo unit from the inside by software. Used to re-power on or reset the alarm after changing the parameter setting.
It is also possible to validate the setting without turning the power back on. Step: Click on the main interface of the host computer to perform a soft reset operation. 14.5.10 Restoring the Factory Value The function is used to restore the parameter to the factory setting. Parameter initialization should note the problems as bellow: 1. Initialization of the parameter setting value must be performed during the servo OFF and it cannot be executed during the servo ON. 2. For the setting to take effect, the servo unit must be turned on again after the operation. 287 SD700 Series Servo Technical Manual