requirements. Installation Protection Requirements This product is a control cabinet mounted product and needs to be installed in the final system for use. The final system should be provided with the appropriate fireproof enclosure, electrical enclosure and mechanical enclosure, etc., and comply with local laws and regulations and relevant IEC standard requirements. When installing the in-cabinet mounting type (IP20) products, please install them in a structure where external objects cannot enter from the top and front. Main Circuit Wiring Requirements Main circuit terminal wiring requirements, please refer to page 41 " 3.1.4 Main circuit wiring requirements" for details.
Protection Device Requirements In order to meet the requirements of the European Union safety standard EN 61800-5-1, please be sure to connect the fuse/circuit breaker at the input side to prevent accidents caused by internal circuit short circuit. Install sufficient branch circuit short circuit protection devices in accordance with applicable regulations and this manual. This product is applicable to circuits with rated fusing capacity below 5000A and maximum voltage of 440VAC (Class 400). Refer to the selection table of "fuse" and "circuit breaker" in the manual for the recommended selection requirements of fuse/filter. Scan the following QR code to download the relevant electronic files:
SD700 Servo drive manual SD700 Servo product catalog 300 SD700 Series Servo Technical Manual