55 SD700 Series Servo Technical Manual /VLT 0x05 In the speed limit, the motor speed is ON after closing the speed limit (closed). /BK 0x06 Brake interlocking, the output of the motor is ON during operation. Refer to “Retaining the brake” for timing details. /WARN 0x07 Warning output. Speed /V-CMP 0x02 Consistent speed output ON when the speed of the servo motor is the same as the command speed (closed). Position /COIN 0x01 Positioning completed output ON (closed) when the difference between the command pulse number and the servomotor movement amount (position deviation) is lower than the position reach range.

/PSELA 0x09 Command pulse override switching can be switched to operate with the value of the input command pulse n times (Pn203). /NEAR 0x08 Positioning close, output ON (closed) when the difference between the positioning command pulse number and the servo motor movement amount (position deviation) is lower than the position proximity signal. PL1 PL2 PL3 3 13 18 Position pulse is power supply for open collector command. Common ALM+ ALM- 31(+) 32(-) OFF (disconnected) at alarm (Output logic can be changed by parameter). PAO /PAO 33 34 Frequency division output A phase signal. PBO /PBO 35 36 Frequency division output B phase signal. PCO /PCO 19 20 Frequency division output C phase signal.