VEICHI — SD700 User Manual 20230516

3.9.3 Confirming the Input Status The status of the input signal can be checked by input signal monitoring (Un100). The Un100 segment display and corresponding Pin No.s are as follows: Up: OFF Down: ON 9 8 7 6 5 4 3 2 1 Codes The upper SEG (LED) lights up when the input signal is OFF. The lower SEG (LED) lights up when the input signal is ON. The value (address: 0XE100) read over the communication is hexadecimal, for example, the read value is 0x1FE. Under the default input configuration, it means that the input of /S-ON (CN1-40) is ON, that is, servo enable, and the input of other input pins is OFF.

3.10 Digital Output Signal 3.10.1 Output Signal Descriptions 54 SD700 Series Servo Technical Manual Display LED Pin No Signal Name 1 CN1-40 /S-ON 2 CN1-41 /P-CON 3 CN1-42 P-OT 4 CN1-43 N-OT 5 CN1-44 /ALM-RST 6 CN1-45 /TLC 7 CN1-46 Reserved 8 CN1-39 Invalid 9 CN1-38 Invalid Control Mode Signal Name Pin No. Descriptions Common /TGON Allocated signals 25(+) 26(-) 27(+) 28(-) 29(+) 30(-) 0x03 ON (closed) when the speed of the servo motor is higher than the set value. /S-RDY 0x00 ON (closed) when servo ON (/S-ON) signal is acceptable. /CLT 0x04 Torque limit ON (closed) when the motor output torque is limited.