2. The switching input signal distribution mode is the parameter configuration (Pn600=1 default parameter). The function of each input signal is configured by the user and is set by parameters Pn601 ~ Pn609. a) Default setting b) Reverse The drive provides reverse input signal switching function in order to facilitate wiring: 1. Take the servo enable (/S-ON) as an example, the default setting is Pn601=0x01. When the signal is ON, the servo is enabled. When the setting is Pn601=0x101, the servo is disabled when the signal is ON. 2. Take the forward limit (POT) as an example, the default setting is Pn602=0x02. When the signal is OFF, the servo forward limit is set.
If the setting is Pn602=0x102, the servo forward stroke limit is released when the signal is OFF. ! 1. Signal ON: The state when the switch input signal (/S - ON, etc.) is connected to the "ground terminal" of the external +24VIN power supply. 2. Signal OFF: The state when the switch input signal (/S - ON, etc.) is disconnected from the "ground terminal" of the external +24VIN power supply. 3. The positive travel limit (POT)/negative travel limit (NOT) of the switch input signal is a valid signal for OFF, and the other input signals are valid signals for ON, so pay attention to the distinction in use.
Cautions c) Always Valid Through the setting of parameters Pn610, Pn611 and Pn612, the configured input signal can always be valid. For example, when Pn610=0x01 (servo enable), the servo is always in the enabled ON state after power-on, and the external enable signal (/ S-ON) does not take effect. ! If the same function is configured on different pin numbers, Er.040 (parameter setting abnormality alarm) will be reported, and the related alarm and handling methods are detailed in "Fault Code and Countermeasures". Cautions 53 SD700 Series Servo Technical Manual Function code NO. of CN1 pins Default function Pn601 40 0x01: Servo enable Pn602 42 0x02: Forward prohibition Pn603 43 0x03:
Reverse prohibition Pn604 41 0x05: Manual PI-P control Pn605 44 0x04: Alarm reset Pn606 45 0x06: Torque limit switching Pn607 46 0x07: Reserved Pn608 39 0x00: Invalid Pn609 38