3.9.2 Input Signal Configuration 1. The digital input signal distribution mode is internally fixed (Pn600=0). The function servo unit of each input signal is internally fixed and cannot be changed. When selecting different control modes, the functions of the pins are different as shown in the following table: 52 SD700 Series Servo Technical Manual Control mode (Pn000) NO.
of CN1 pins 40 42 43 41 44 45 46 38/39 0- Position control /S-ON servo enable P-OT forward limit N-OT reverse limit /P-CON proportional control /ALM-RST alarm clear /TLC torque limit switching Reserve d Invalid 1- Analog speed 2- Torque control 3- Internal speed /SPD-D internal speed command direction selection /SPD-A internal speed command selection A /SPD-B internal speed command selection B 4- Internal speed analog speed 5- Internal speed position 6- Internal speed torque 7- Position analog speed /C-SEL control mode switching /TLC torque limit switching Reserved 8- Position torque 9- Torque analog speed 10- Speed speed control with zero fixed function /ZCLAMP zero Position fixed 11- Speed position control with command pulse inhibit function /INHIBIT command pulse prohibition