3.11.3 Sequence Control Input Circuit The following describes the 38 to 46 terminals of the CN1 port. Connect via a relay or open collector transistor circuit. When using a relay connection, select the relay for the minute current. If you do not use a minute current relay, it will cause poor contact. Examples for Relay Circuit Examples for Open - Collector Circuits Note: The external power supply (DC24V) must have a capacity of 50 mA or more. The input loop of the servo unit uses a bidirectional optocoupler. Please select the sink circuit connection or the source circuit connection according to the specifications of the machine.
3.11.4 Sequence Output Loop Servo unit signal output circuit is the following three kinds: 1. Open collector output circuit The output signal (SEN, OCZ) is an open collector transistor output circuit. Please receive through optocoupler circuit, relay circuit or linear receiver circuit. Optocoupler loop example Relay circuit example Controller VCC VCC Controller Servo drive Servo drive OCZ SEN OCZ SEN GND Twisted wire GND Twisted wire 2. Optocoupler output circuit The brake linkage (/BK), servo alarm (ALM), servo ready (/S-RDY) and other sequence output signals belong to the optocoupler output circuit. Connect via relay or line receiver circuit.
61 SD700 Series Servo Technical Manual DC24V 47 SERVOPACK +24VIN 4.7kΩ /S-ON SERVOPACK E.g., C24V 47 SERVOPACK +24VIN SERVOPACK E.g. 4.7kΩ , /S-ON